Blown-In Insulation Calculator

Enter the attic floor size or area, choose a blowing wool with a published coverage chart and the R-value you are aiming for. You’ll see how many bags the chart calls for and the minimum depth the insulation must reach. For any other product, enter the coverage per bag from its own chart.

Example values are filled in. Replace them with your own measurements.

Measure by

Measure the floor area you will insulate, inside the exterior walls.

Coverage chart

Only products whose attic coverage chart is quoted from the maker are listed. For any other product, choose “my own product” and use the chart printed on its bag.

The R-value of the new insulation layer. What your attic needs is set by your local energy code – check with your building department.

Optional extra on top of the chart. The chart’s bag count is already a minimum for the stated R-value.

Material needed

Bags
23
Area to insulate
1,200 sq ft
Coverage per bag
52.63 sq ft
Minimum installed thickness
13.5 in
  • The makers state that the R-value is reached only with at least this number of bags and at least the minimum thickness. If you reach the thickness with fewer bags, the insulation is too fluffy – keep blowing until both are met.
  • The R-value an attic needs is set by your local energy code and climate zone. Check with your building department before choosing a target.

Optional. Enter your supplier’s price – we never fill in prices for you.

Estimates only. Actual material requirements may vary – verify manufacturer specifications before you buy.

Drawn to scalePlan view 40 ft × 30 ft, area 1,200 sq ft
23 bags to buy

How it works

The calculator finds the attic floor area and reads the number of bags per 1,000 sq ft and the minimum thickness from the maker’s chart for the R-value you choose.

Area = Length × Width  or  entered directly
Bags = ⌈ Area (sq ft) × (1 + Extra ÷ 100) × Bags per 1,000 sq ft ÷ 1,000 ⌉
Own product: Bags = ⌈ Area × (1 + Extra ÷ 100) ÷ Coverage per bag ⌉

⌈ ⌉ means rounding up to the next whole bag. Metric areas are converted to square feet before the chart is applied.

Worked example in words

A 40 × 30 ft attic floor is 1,200 sq ft. For R-38, Owens Corning’s AttiCat chart calls for 19 bags per 1,000 sq ft, so 1,200 × 19 ÷ 1,000 = 22.8 – buy 23 bags. Each bag covers at most 1,000 ÷ 19 ≈ 52.6 sq ft, and the insulation must be at least 13.5 in deep once installed.

Reading a coverage chart

Every bag of blown-in insulation carries a chart with one row per R-value. The columns that matter are the minimum number of bags per 1,000 sq ft (or the maximum area one bag may cover) and the minimum installed thickness. Owens Corning’s fact sheet states that the R-value is provided by installing the required number of bags at no less than the minimum thickness, and that falling short on either lowers the R-value. Both charts quoted here also list extra bags and depth for very cold Minnesota winter design temperatures.

Products and charts

The two presets are quoted from Owens Corning’s AttiCat fact sheet (27.5 lb bag) and Johns Manville’s Climate Pro B7600 attic card. Bag weights and charts change between products and over time, so compare the chart on the bag you buy, and use “my own product” for cellulose or any other blowing wool.

Worked example

Inputs

Measure by
Attic length × width
Attic length
40 ft
Attic width
30 ft
Coverage chart
Owens Corning AttiCat (27.5 lb bag)
R-value to reach
R-38
Extra allowance
0 %

Result

Area to insulate
1,200 sq ft
Coverage per bag
52.63 sq ft
Minimum installed thickness
13.5 in
Bags
23

Common mistakes

  • Buying by depth alone. The R-value on the chart needs both the minimum number of bags and the minimum thickness – blowing loosely can reach the depth with too little material.
  • Using one brand’s chart for another. Bag weights and coverage differ between products; at R-38, for example, the AttiCat chart calls for 19 bags per 1,000 sq ft and the Climate Pro chart for 17.7.
  • Measuring the roof instead of the attic floor. Blown-in insulation is laid on the attic floor, so measure the ceiling below it.
  • Ignoring existing insulation. These charts are for the R-value of the new layer; how much old insulation adds depends on its type and condition.
  • Covering soffit vents or recessed lights. Keep vents clear with baffles and follow the fixture maker’s rules for clearance.

Assumptions and limits

  • In dimension mode the attic floor is one rectangle of length × width.
  • Coverage comes from the maker’s attic chart for open-blown applications at the chosen R-value; the bag count is rounded up after any extra allowance.
  • Joists, trusses and other framing are not subtracted – the charts are stated per net area of attic floor.
  • The calculator does not account for existing insulation, the Minnesota cold-climate additions printed on both charts, walls or enclosed cavities.
  • This is a material quantity only. It does not choose an R-value, air sealing, baffles or a vapor retarder – those follow your local code.

Frequently asked questions

How many bags of blown-in insulation do I need for 1,000 sq ft?

It depends on the product and the R-value. Owens Corning’s AttiCat chart calls for 14.6 bags per 1,000 sq ft for R-30, 19 for R-38, 25 for R-49 and 31.5 for R-60. Johns Manville’s Climate Pro chart calls for 13.7, 17.7, 23.4 and 29.2 bags for the same R-values.

How deep should blown-in insulation be for R-38?

For AttiCat the chart’s minimum installed thickness for R-38 is 13.5 in; for Climate Pro it is 13.4 in. Other products differ, so use the chart on your bag.

How much does one bag of blown-in insulation cover?

Less as the R-value rises. An AttiCat bag covers at most 52.6 sq ft at R-38 and 31.8 sq ft at R-60, according to Owens Corning’s chart. The chart on the bag lists the maximum coverage for each R-value.

What R-value do I need in my attic?

That is set by the energy code where you live and depends on your climate zone. This calculator doesn’t recommend a value – check with your local building department.

Can I blow new insulation over old insulation?

Often, but the old layer’s R-value depends on its type, depth and condition, and the charts here are for the new layer alone. Enter the R-value you want the new layer to add, and ask the maker or an energy auditor if you are unsure.

Sources

Method reviewed November 5, 2026

Privacy choices

Choose whether this site may use analytics cookies to measure which calculators are used. Your calculator inputs are never sent.